The PJ series aluminum pump jack components are versatile, dependable, and easy to operate. Featuring field-replaceable components, they are compatible and interchangeable with the leading competitor. Pump jacks, aluminum poles, support braces, work benches, end rail kits, and safety nets are included in this series and work with Werner Nestable Stages.




Features

  • Aluminum frame Z channel is 20% stronger than leading competitor
  • Large boot strap and slip resistant lever
  • Interchangeable with leading competition


Specifications

FeatureSize / Details
ComponentPump Jack
CertificationsANSI A10.8 (2001); OSHA
Approx. Cu. Ft. Per Unit3.47
Approx. Shipping Wt. Lbs.35




Package Contents

Part NumberQtyDescription

Dimensions

FeatureSize


Additional PJ Series Models

Model No.ComponentApprox. Cu. Ft. Per UnitApprox. Shipping Wt. Lbs.
PJ-100Pump Jack3.4735
PJ-12PPole0.8528
PJ-18PPole1.2742
PJ-24PPole1.6956
PJ-6PPole0.4315
PJ-ERNEnd Rail Kit1.1620
PJ-ERWEnd Rail Kit1.1620
PJ-PCPole Connector0.4614
PJ-PF-4Pole Foot0.153
PJ-SBFFoldable Support Brace0.7110
PJ-SBRRigid Support Brace2.7214
PJ-SNSafety Net0.8910
PJ-WBWork Bench2.0620


(32 Questions : 32 Answers)

Product Q&A

Ask your questions. Share your answers.

 
 
« Back
 
 
PJ-WB Aluminum Pump Jack Work Bench
 
1 answer

What is the length of the workbench

Customer avatar
by
Anonymous
3 weeks ago
Customer avatar
by
Anonymous
0points
0out of 0found this question helpful.
Was this helpful?helpful0unhelpful0

Answers

Answer: 
Closed is 20.450" and opened is 31.695"
2 weeks, 6 days ago
Customer avatar
by
Read all my Q&A
 
Please wait while more information about Werner Customer Care is loaded.
Additional information about Werner Customer Care could not be loaded.
0points
0out of 0found this answer helpful.
Was this helpful?helpful0unhelpful0
PJ-100 Aluminum Pump Jack
 
1 answer

Can you ship me a set of pump jacks to Czech Republic? I will pay postage of course.

Customer avatar
by
Radim Kracmar
Ostrava, Czech Republic
3 months, 1 week ago
Customer avatar
by
Radim Kracmar
Ostrava, Czech Republic
Age: 35-44
Gender: Male
0points
0out of 0found this question helpful.
Was this helpful?helpful0unhelpful0

Answers

Answer: 
Please contact our Customer Care Department when convenient at 888-523-3370 Monday through Friday 8 AM till 5 PM EST for further details on your issue and/or question.
3 months ago
Customer avatar
by
Read all my Q&A
 
Please wait while more information about Werner Customer Care is loaded.
Additional information about Werner Customer Care could not be loaded.
0points
0out of 0found this answer helpful.
Was this helpful?helpful0unhelpful0
PJ-24P Aluminum Pump Jack 24 ft Pole
 
1 answer

Werner post rubber

Customer avatar
by
Oscar
Houston
2 months, 1 week ago
Customer avatar
by
Oscar
Houston
Can the rubber in the aluminum posts be replaced thanks
0points
0out of 0found this question helpful.
Was this helpful?helpful0unhelpful0

Answers

Answer: 
We don't have replacement parts for the poles.
They cannot be replaced.
2 months, 1 week ago
Customer avatar
by
Read all my Q&A
 
Please wait while more information about Werner Customer Care is loaded.
Additional information about Werner Customer Care could not be loaded.
0points
0out of 0found this answer helpful.
Was this helpful?helpful0unhelpful0
PJ-100 Aluminum Pump Jack
 
1 answer

Any suggestions for stairway sccaffold

Customer avatar
by
drywall
california
4 months ago
Customer avatar
by
drywall
california
Age: 45-54
Gender: Male
Im a drywall contractor
0points
0out of 0found this question helpful.
Was this helpful?helpful0unhelpful0

Answers

Answer: 
I don't have any suggestions. Our scaffolds are to be used on a level surface, not stairs.
2 months, 1 week ago
Customer avatar
by
Read all my Q&A
 
Please wait while more information about Werner Customer Care is loaded.
Additional information about Werner Customer Care could not be loaded.
0points
0out of 0found this answer helpful.
Was this helpful?helpful0unhelpful0
PJ-100 Aluminum Pump Jack
 
1 answer

can you use the jacks on interior stairways

Customer avatar
by
drywall
california
4 months, 1 week ago
Customer avatar
by
drywall
california
Age: 45-54
Gender: Male
0points
0out of 0found this question helpful.
Was this helpful?helpful0unhelpful0

Answers

Answer: 
We do not suggest using pump jacks indoors for safety purposes. The feet for the poles are not manufactured or tested indoors.
4 months ago
Customer avatar
by
Read all my Q&A
 
Please wait while more information about Werner Customer Care is loaded.
Additional information about Werner Customer Care could not be loaded.
+1point
1out of 1found this answer helpful.
Was this helpful?helpful1unhelpful0
PJ-100 Aluminum Pump Jack
 
1 answer

Can pump jack poles be painted?

Customer avatar
by
Otis
Seattle, WA, USA
5 months, 3 weeks ago
Customer avatar
by
Otis
Seattle, WA, USA
Age: 55-65
Gender: Male
0points
0out of 0found this question helpful.
Was this helpful?helpful0unhelpful0

Answers

Answer: 
Pump jack poles can not be painted. Doing so can alter the efficiency in which the pump jack operates.
5 months, 1 week ago
Customer avatar
by
Read all my Q&A
 
Please wait while more information about Werner Customer Care is loaded.
Additional information about Werner Customer Care could not be loaded.
0points
0out of 0found this answer helpful.
Was this helpful?helpful0unhelpful0
Series PJ Aluminum Pump Jack Components
 
1 answer

Can your pump jacks be used to lift a beam into position 20' high

Customer avatar
by
Voyager
Damascus, Maryland
5 months, 2 weeks ago
Customer avatar
by
Voyager
Damascus, Maryland
Age: 55-65
Gender: Male
Beam in question is PT Glulam, about 5" x 14" x 28' long
0points
0out of 0found this question helpful.
Was this helpful?helpful0unhelpful0

Answers

Answer: 
Our pump jacks can not be used in this application.
5 months, 1 week ago
Customer avatar
by
Read all my Q&A
 
Please wait while more information about Werner Customer Care is loaded.
Additional information about Werner Customer Care could not be loaded.
0points
0out of 0found this answer helpful.
Was this helpful?helpful0unhelpful0
PJ-100 Aluminum Pump Jack
 
1 answer

can i span 46 ft with two 2' x 32' alum stages and 3 alum poles & pump jacks ?

Customer avatar
by
Jack
New Orleans, LA, USA
8 months ago
Customer avatar
by
Jack
New Orleans, LA, USA
Age: 55-65
Gender: Male
braces at 13 ft with top brace at 28 ft on alum poles
top stage no higher than 24 ft
0points
0out of 0found this question helpful.
Was this helpful?helpful0unhelpful0

Answers

Answer: 
Please contact our Customer Care Department when convenient at 888-523-3370 Monday through Friday 8 AM till 5 PM EST for further details on your issue and/or question.
8 months ago
Customer avatar
by
Read all my Q&A
 
Please wait while more information about Werner Customer Care is loaded.
Additional information about Werner Customer Care could not be loaded.
-1point
0out of 1found this answer helpful.
Was this helpful?helpful0unhelpful1
Series PJ Aluminum Pump Jack Components
 
1 answer

width of stage and pump jack

Customer avatar
by
sadhu
Bronx, NY, USA
10 months ago
Customer avatar
by
sadhu
Bronx, NY, USA
Age: 35-44
Gender: Male
I have 16 inchs between two houses the I need to get up between the two to install siding, is there a set up that will fit in 16 inch space
0points
0out of 0found this question helpful.
Was this helpful?helpful0unhelpful0

Answers

Answer: 
Anyone using a Pump Jack would need at least 36” from the structure where the attachment brace is mounted to the back side of the pole. Depending what is behind the attachment brace, they would need an additional 4-6 inches from the back of the pole (rubber side) to the end of the T-Handle on the mounting brace.
10 months ago
Customer avatar
by
Read all my Q&A
 
Please wait while more information about Werner Customer Care is loaded.
Additional information about Werner Customer Care could not be loaded.
0points
0out of 0found this answer helpful.
Was this helpful?helpful0unhelpful0
1 year, 1 month ago
Customer avatar
by
Dan
Maryland
Age: 35-44
Gender: Male
0points
0out of 0found this question helpful.
Was this helpful?helpful0unhelpful0

Answers

Answer: 
Per OSHA a guardrail system can be any material such as screens, mesh, intermediate vertical members, etc. They need to be installed between the top edge of the guardrail system and the walking/working surface when there is no wall or parapet wall at least 21 inches high. These materials that can be used as a guardrail shall be capable of withstanding a force of at least 150lbs applied in any downward or outward direction. The PJ-SN complies with all these things. We do have installation instructions available for the PJ-SN. If you would like a copy of these please contact customers care M-F 8am-5pm EST at 888-523-3370.
1 year, 1 month ago
Customer avatar
by
Read all my Q&A
 
Please wait while more information about Werner Customer Care is loaded.
Additional information about Werner Customer Care could not be loaded.
0points
0out of 0found this answer helpful.
Was this helpful?helpful0unhelpful0
2next>>
  • 2016-08-16 T05:58:17.525-05:00
  • bvseo_lps, prod_bvqa, vn_prr_5.6
  • cp-1, bvpage1
  • co_hasquestionsanswers
  • loc_en_US, sid_PJ-100, prod, sort_default
2next>>



Different types of ladders are designed to keep you safe and productive when climbing or standing. Using the wrong style of ladder or simply ignoring the limitations of climbing equipment can result in a fall or serious injury.
Height is referring to the actual ladder height. Extension ladders should be 7 to 10 feet longer than the highest support or contact point, which may be the wall or roof line. The highest standing level is four rungs down from the top. The highest permitted standing level on a stepladder is two steps down from the top.

Reach height is the maximum reach assuming a 5’6” person with a vertical 12” reach.
Ladders are designed to safely hold up to a specific amount of weight. The Werner Performance System defines five different capacities using a color and star rating system. The Duty Rating is defined as the maximum safe load capacity of the ladder. A person’s fully clothed weight plus the weight of any tools and materials that are carried onto the ladder must be less than the load capacity.

Werner offers ladder made from fiberglass and aluminum. Each material has characteristics which make it best for certain applications, or one material may simply fit the personal preferences of the user. For example, if working around electricity users should select fiberglass products due to their non-conductive side rails.